<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-05 06-26-27
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.30 MHz 5/5, 62 dBuV NRJ
Pilot RDS Phase Difference
7.0 kHz 3.8 kHz 1 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 74 kHz 10040 5,2789
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
9,2 dBr 9,95 dBr 10,4 dBr 29,5
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" NRJ " F220 0 (No PTY) 1 0 1 2 6:26, 5.01.2025
RT
"NRJ : CARBONNE - Comment Te Remplacer "
AF EON
89.2, 90.2, 90.8, 92.2, 96.4, 97.7, 100.0, 100.1, 100.3, 100.4, 100.5, 101.7, 103.0, 103.3, 106.6, 106.9 MHz -
FM Scope Station: 100.30 MHz, signal: 5/5 (62 dBuV) Max at: 74 kHz MIN: 11 kHz % above 75 kHz: 5,2789 Acquired: 2025/01/05 6:25:23 Total samples: 10040 Equivalent time: 0:08:22 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000
FM Scope MAX: 10,4 dBr MIN: 9,2 dBr AVE: 9,95 dBr % above 10,0 dBr: 29,5 Last value: 9,6 dBr (2025/01/05 6:25:22) Station: 100.30 MHz, signal: 5/5 (62 dBuV) 06:19 06:20 06:21 06:22 06:23 06:24 06:25 0 50 100 Dev. MAX [kHz] 0 5 10 Pm [dBr] 0 5 Signal Quality